eTCX

eTCX
High Efficiency Tower Clean Systems
Basin Sweeping Flow Range: 50 - 910 U.S. gpm (11 - 184 m3/hr)
Side Stream Flow Range: 65 - 810 U.S. gpm (15 - 184 m3/hr)
High Efficiency Tower Clean Systems
Basin Sweeping Flow Range: 50 - 910 U.S. gpm (11 - 184 m3/hr)
Side Stream Flow Range: 65 - 810 U.S. gpm (15 - 184 m3/hr)
- Filter performance, independently tested, rated to remove 98% of solids 44 micron and larger in a single pass, and 99% of solids 25 microns and larger in recirculating applications.
- eTCX Systems feature LAKOS eHTX Separator, Premium Efficiency pump, higher capacity (12 liters) Solids Recovery Vessel and/or Fail-Safe Automated Purge valve, and SmartStart Control Panel.
- SmartStart Control Panel features motor overload protection, under-power (dry run) conditions, and automatic fault logging.
Our highest efficiency Cooling Tower Basin Cleaning and Side Stream filtration system removes fine solids* (25 microns and larger) from HVAC open and closed loops. This packaged system reduces manual basin cleaning, equipment operating costs, maintenance costs, and water use.
* 2.6 specific gravity and heavier
CLICK HERE to watch the Cooling Tower Basin Cleaning Animation
PRODUCT CONFIGURATOR
* 2.6 specific gravity and heavier
CLICK HERE to watch the Cooling Tower Basin Cleaning Animation
PRODUCT CONFIGURATOR
- MODELS
- OPTIONS
- DATASHEET
- MANUAL
- SPEC SHEET
-
Basin Sweeping Configuration
Models Download Flow Rates1 Diffuser/Strainer
inlet4Separator
outletSystem Weight Pump HP/kW2 US gpm m3/hr lbs kgs eTCX-0050-SRV DWG PDF 50 11 2-1/2” 1-1/4” 558 264 1.5 HP/1.1 kW eTCX-0080-SRV DWG PDF 80 18 2-1/2” 1-1/2” 568 257 2 HP/1.49 kW eTCX-0110-SRV DWG PDF
110 25 3” 2” 683 309 3HP/2.23 kW eTCX-0160-SRV DWG PDF 160 36 4” 2-1/2” 832 377 5 HP/3.72 kW eTCX-0210-SRV PDF 210 48 4” 3” 875 396 7.5 HP/5.59 kW eTCX-0310-SRV DWG PDF 310 70 6” 4” 1109 502 7.5 HP/5.59 kW eTCX-0410-SRV DWG PDF 410 93 6” 4” 1233 555 10 HP/7.45 kW eTCX-0610-SRV DWG PDF 610 138 6” 4” 1859 845 20 HP/14.8 kW eTCX-0910-SRV6 Consult factory 910 206 8” 6” 2493 1133 25 HP/18.7 kW
Models Download Flow Rates1 Diffuser/Strainer
inlet4Separator
outletSystem Weight Pump HP/kW2 US gpm m3/hr lbs kgs eTCX-0050-SRV DWG PDF 65 5 2-1/2” 1-1/4” 558 267 1.5 HP/1.1 kW eTCX-0080-SRV DWG PDF 95 22 2-1/2” 1-1/2” 568 257 2 HP/1.49 kW eTCX-0110-SRV DWG PDF 140 32 3” 2” 683 309 3HP/2.23 kW eTCX-0160-SRV DWG PDF 210 48 4” 2-1/2” 832 377 5 HP/3.72 kW eTCX-0210-SRV PDF 250 57 4” 3” 875 396 7.5 HP/5.59 kW eTCX-0310-SRV DWG PDF 365 83 6” 4” 1109 502 7.5 HP/5.59 kW eTCX-0410-SRV DWG PDF 500 114 6” 4” 1233 555 10 HP/7.45 kW eTBX-0610-SRV DWG PDF 610 138 6” 4” 1644 747 10 HP/7.45 kW eTBX-0810-SRV5 Consult factory 810 184 8” 6” 2219 1007 15 HP/11.2 kW
1 Higher flow rates available. Contact LAKOS.
2 Models 0050 and 0080 use 3500RPM.
3 Contact LAKOS for motor specific FLA.
4 Minimum suction pipe size is equivalent to system’s diffuser inlet. Pump NPSHR and piping to-and-from LAKOS Systems should be reviewed and sized accordingly. Consult LAKOS for design assistance if length of suction line is more than 25’ or has several elbows or elevation changes.
5 eTBX-0810 units are 22 1/2 deg. low profile.
6 eTCX-0910 used to be model eTCX-0810 previously. Pump HP remains the same.
DimensionsModels Dim A Dim B Dim C inches mm inches mm inches mm eTCX-0050-SRV 24 610 39-3/4 1010 38-15/16 989 eTCX-0080-SRV 29-1/2 749 45 1143 45-1/4 1149 eTCX-0110-SRV 29-1/2 749 45 1143 50-11/16 1287 eTCX-0160-SRV 29-1/2 749 45 1143 59-1/2 1511 eTCX-0210-SRV 29-1/2 749 45 1143 66-11/16 1694 eTCX-0310-SRV 31-1/2 800 45 1143 76-5/8 1946 eTCX-0410-SRV 31-1/2 800 45 1143 82 2083 eTCX/eTBX-0610-SRV 36 914 49-3/4 1264 95-1/2 2426 eTBX-0810-SRV 46-1/2 1181 123-3/4 3143 67-1/2 1715 eTCX-0910-SRV 46-1/2 1181 123-3/4 3143 61-1/2 1715
factory for detailed dimensions.
-
Inlet/Outlet Valve Kit Adders:
eTCV Valve Kit, 2 Tower Alternating Valve Kit
SRV Systems Adders:
SRI, DEC, Replacement Bags
Pump Repair Kit Adder
ASME
Internal 3M Scotchkote Coating
Stainless Steel Material
-
-
-